Glycated Hemoglobin HbA1c Analyzers: Definition, Functions, Classification, And Applications

The glycated hemoglobin analyzer is an instrument that best reflects the degree of binding of hemoglobin to glucose and is used to measure HbA1c. Glycated hemoglobin is a good indicator of disease control in patients with diabetes and can reflect staged blood sugar levels. Glycated hemoglobin HbA1c is an effective detection indicator for diabetes screening, diagnosis, blood sugar control, and efficacy assessment, and has been widely used in clinical practice. The advantage of the glycated hemoglobin analyzer is that it is fast and accurate, and can help doctors promptly assess the blood sugar control of diabetic patients and adjust treatment plans in a timely manner. The disadvantage is that the equipment is relatively expensive, requires certain maintenance and usage costs, and also requires professional technicians to operate and maintain.

The red blood cells in human blood contain hemoglobin, which we often call hemoglobin. When glucose in the blood comes into contact with hemoglobin, the two will cross-link together to form glycated hemoglobin, which is a stable compound in which glucose in human blood is covalently bonded to the N-terminal valine residue of the hemoglobin ß chain. When the concentration of glucose in the blood is high, the amount of glycated hemoglobin formed by the body is relatively high. Generally speaking, the lifespan of human red blood cells is 120 days. Before the death of human red blood cells, the content of glycated hemoglobin in the blood will remain relatively unchanged. From this point of view, the content of glycated hemoglobin in the blood changes approximately every 120 days. Therefore, the glycated hemoglobin content reflects the average blood sugar level in the past 2-3 months. Currently, the proportion of HbA1c to total hemoglobin (%) is often used clinically to express the concentration of HbA1c.

HbA1c Analyzer

It is generally believed that the relationship between the glycated hemoglobin (HbA1c) detection level and blood sugar in patients with type II diabetes is as follows:

3.8%~5.8%: Blood sugar is under normal control.

5.8%~7%: ideal blood sugar control.

7% to 8%: Blood sugar control is average.

8% to 9%: The control is not ideal. It is necessary to strengthen blood sugar control, pay more attention to diet and exercise, and adjust the treatment plan under the guidance of a doctor.

>9%: Poor blood sugar control is a risk factor for the development of chronic complications, which may cause complications such as diabetic nephropathy, arteriosclerosis, and cataracts, and may lead to acute complications such as ketoacidosis.

Glycated hemoglobin analyzers currently on the market can be divided into two types: offline and online. Offline glycosylated hemoglobin analyzers usually require blood samples to be sent to a specialized laboratory for analysis, and it takes a certain amount of time to obtain results. The online glycosylated hemoglobin analyzer can achieve real-time detection and is suitable for hospitals, clinics and other places. The application of glycosylated hemoglobin detection can be used for the following points:

(1) It can be used as a diagnostic test for diabetes.

(2) It can be used as a detection method to assess the risk of complications.

(3) As a testing method for screening high-risk groups for diabetes.

(4) It has certain significance for judging different stages of diabetes.

(5) It is the gold standard for measuring blood sugar control and plays a positive role in adjusting treatment plans and discovering problems in treatment.

(6) Can be used for differential diagnosis with other diseases. For example: Under stress conditions such as cerebrovascular emergencies, blood sugar increases but glycated hemoglobin does not.

(7) In the management of gestational diabetes, it is not enough to control blood sugar alone. The level of glycated hemoglobin should also be controlled, which has a positive effect on preventing eclampsia, macrosomia, teratogenesis, and stillbirth.

HbA1c Analyzer

Why Choose Us?

CN MEDITECH

CNMEDITECH is dedicated to the long-term research of the HbA1c analyzer market. Our mission is “People oriented and win-win strategy,Matching the real needs of the region with a focus on human health,To be the world’s first-class medical field solution expert”. We have been manufacturing high-quality medical device products for more than ten years.

We have built our reputation on delivering quality healthcare solutions on time and on budget. All our products comply with international health and safety regulations and all products come with a warranty.

Are you still worrying about your customer’s product needs? Are you still angry that the product is expensive?Our HbA1c analyzers have various models and support personalized product customization.

Our company has many styles to choose from. In addition, we have high-quality pre-sales consulting guidance and professional after-sales service, all to meet your needs.

Whether it is a cost-effective or high-end product, there will always be something suitable for you. If you have any needs for products, you can ask us, our factory will meet your needs as soon as possible, and we will make every effort to provide you with solutions.Feel free to send us your inquiries.